Electricity, battery and solar calculators

Calculators for watts, kilowatt-hours, running cost, batteries, backup power, solar sizing and EV charging, plus short guides for the terms those tools use.

Convert units

Power is a rate. Energy is that rate multiplied by time. A 1,000 W heater run for one hour uses 1 kWh; the same heater run for two hours uses 2 kWh. The watts to kWh converter goes either way. The kW vs kWh guide spells out that distinction: a bill’s kilowatt-hours are not the same question as a device’s kilowatts.

If you have volts and amps instead of watts, a resistive load is voltage times current. Many real loads also need a power factor. The watts to amps calculator takes the voltage you enter, an optional power factor, and a single-phase or three-phase choice. kVA to kW writes the same relationship in kilovolt-amperes. The guides are volts, amps and watts, power factor and three-phase power.

Battery labels are often in milliamp-hours. That is electric charge, not energy, until you multiply by voltage. The mAh to Wh calculator uses the voltage you type. AC vs DC explains why a battery or a solar array is direct current and a wall socket is alternating current. Heating and cooling equipment is often rated in BTU per hour. The BTU to watts converter uses the International Table BTU, and BTU and watts explains what that rating is counting.

Running cost

A bill charges for energy, usually in kilowatt-hours, at a unit rate, then adds standing charges and taxes. The electricity cost calculator multiplies kilowatt-hours, or watts and hours converted first, by the rate you type. It prices that energy only, not the rest of the bill. How to read an electricity bill shows which line is the unit rate. Time-of-use rates explains which rate to use when the bill has peak and off-peak prices. You type the rate each time; tariffs are not stored.

The appliance energy calculator is the same sum for one device, with an optional second load so two nameplate ratings can be compared at the hours you expect them to run. What uses the most electricity at home is about duty cycle: a modest wattage left on for many hours can cost more than a large wattage used briefly. LED vs incandescent separates lumens (brightness) from watts (power). Appliance labels explains why a nameplate and a standardised kWh-per-year figure are not your household’s usage.

Electric resistance heat and a heat pump do not draw the same power for the same warmth. The electric vs gas calculator uses the COP or AFUE you enter, your electricity rate and your gas rate. How a heat pump uses electricity explains COP before you type one.

Backup and runtime

How long a battery runs is the energy you can actually take out, divided by the load. The battery runtime calculator uses the watt-hours you enter, the depth of discharge and efficiency you enter, and the watts of the load. It can turn the sum around to a capacity, or estimate charge time. How a battery works defines those terms. Types of batteries compares flooded lead-acid, AGM, gel, LiFePO4, lithium-ion and NiMH on one page.

A UPS uses that same straight-line energy balance, plus a check that volt-amperes cover the watts at the power factor you enter. Manufacturer runtime charts bend; the UPS runtime calculator is a straight-line estimate, not one of those charts. How a UPS works covers offline, line-interactive and online types, and VA versus watts.

A portable power station is a battery and an inverter sold as one unit. The power station runtime calculator uses the same runtime sum, and it can include solar input when you type it. Portable power stations explains what that box is, next to a bare inverter and a fuel generator. Series vs parallel covers adding voltage or adding amp-hours when the bank is built from more than one battery. It does not size wire.

A generator or an inverter has to cover the loads while they run, and the extra draw when the largest motor starts. You type the list. Running watts add up. Starting watts are the other loads that stay on, plus the largest surge. The generator size calculator and the inverter size calculator both work that way. Starting vs running watts explains the surge. Inverter types covers pure sine, modified sine, and off-grid versus grid-tie. If the open question is which machine you need, backup power options compares a UPS, an inverter, a power station and a generator.

Solar from a known load

The solar tools size equipment from energy use you already know, not from a location lookup, a weather-based yield estimate or a payback model.

The solar panel size calculator divides daily kilowatt-hours by the panel rating, the peak sun hours you enter, and a system efficiency you enter. Peak sun hours are equivalent hours at full sun, not a time of day. Peak sun hours defines that figure; it is not a map of locations. How solar panels work covers the cells, watts and energy behind the sum. Types of solar panels compares monocrystalline, polycrystalline and thin-film without a product list. Grid-tie, off-grid and hybrid shows how the parts connect. RV solar applies the same math to a 12 V bank with a small roof.

The solar battery calculator turns daily use, days of storage, depth of discharge and efficiency into a bank size. Home solar battery storage describes what that bank does with the panels, including AC-coupled and DC-coupled storage, still without a payback model. The charge controller calculator estimates current from array watts and battery voltage. Its safety factor starts at 1.00; you raise it yourself if you want a margin. PWM vs MPPT explains which kind of controller that current is for.

EV charging and range

The EV charging calculator estimates hours from the kilowatt-hours you want to add, or from pack size and state of charge, using the charger kilowatts and a charging efficiency you type. It then prices the energy drawn from the wall at your rate. It leaves out the slowdown near the end of a charge. EV charging levels describes Level 1, Level 2 and DC fast charging in those terms. Home EV charging is about choosing a charger power at home. It does not size wire or breakers.

The EV range calculator divides usable kilowatt-hours by the efficiency you enter, and it can price that energy per mile or per kilometre at your rate. EV range and efficiency explains watt-hours per mile and kilowatt-hours per 100 km, and why speed and cabin heat change the figure you type.

You supply the figures

A nameplate wattage, the hours a device runs, the unit rate on a bill, a battery’s watt-hours, a panel rating, a charger’s kilowatts: those are the inputs. Each calculator shows the formula it uses and names its sources. The result is an estimate, not professional electrical, energy, solar or automotive advice, and not a substitute for a qualified electrician, installer or manufacturer specification. When a page needs a price, an efficiency, a depth of discharge or hours of sun, you enter it.

Where a tool asks for voltage, 120 V and 230 V are shortcuts for common AC supplies, and 12 V, 24 V and 48 V are shortcuts for common DC banks. Any of them can be replaced with the number on the equipment.