Types of batteries
Consumer and light off-grid systems usually meet flooded lead-acid, AGM, gel, LiFePO4, other lithium-ion, or NiMH. The comparison below is qualitative. Numeric limits (depth of discharge, cycle life, charge voltages) belong on the product datasheet.
How to read this comparison
Dimensions that matter for everyday choice: nominal voltage (often a pack rating that varies by cell count), how deeply the chemistry is usually discharged in practice, rough cycle-life behaviour, temperature sensitivity, maintenance, and typical use.
Lead-acid is usually used at a shallower depth of discharge than LiFePO4. Exact DoD percentages, cycle counts, cell voltages and “hours at C/20” belong on the manufacturer’s datasheet.
Background on charge, Ah vs Wh and the linear usable-energy model: how a battery works.
Flooded lead-acid
Flooded (vented) lead-acid packs are a long-standing backup and automotive chemistry. Nominal pack voltage is set by how many cells are series-connected; many consumer DC systems use common “12 V-class” packs, but the right figure is always the nameplate.
In practice they are usually not discharged as deeply as lithium chemistries intended for deep cycling. They need periodic watering and ventilation for gas during charge. Cycle life and allowable depth of discharge are manufacturer values.
Typical use: automotive starting, some UPS internals, and budget off-grid banks where maintenance is acceptable.
AGM and gel (sealed lead-acid)
AGM (absorbed glass mat) and gel are sealed lead-acid variants. They still use lead-acid electrochemistry, but the electrolyte is immobilised, so they are generally lower-maintenance than flooded and often preferred where spilling must be avoided.
Compared with flooded of similar duty, usable depth of discharge and cycle life still depend on the product datasheet. They remain lead-acid: usually run more conservatively on depth of discharge than LiFePO4 deep-cycle packs. Charge voltage limits differ between AGM and gel, so follow the manufacturer.
Typical use: UPS batteries, mobility aids, marine and RV accessory banks where sealed construction matters.
LiFePO4
Lithium iron phosphate (LiFePO4) is a lithium-ion family chemistry common in fixed storage and portable power stations. Pack voltage is set by series cell count; always use the stated nominal voltage for Wh math.
In product marketing and off-grid practice, LiFePO4 is usually allowed a deeper usable depth of discharge than lead-acid of similar nameplate Wh, but you should still enter the DoD the manufacturer supports. Cycle life is often described as long relative to lead-acid for similar duty; exact cycle counts need a cited datasheet.
Temperature: charging below freezing is a known constraint for many lithium packs; check the manufacturer’s charge window. Typical use: solar storage, UPS-style DC banks, portable power stations.
Other lithium-ion
“Lithium-ion” covers several cathode chemistries beyond LiFePO4 (for example cobalt- or nickel-rich consumer-electronics cells). Pack energy density and voltage windows vary; the nameplate voltage and Wh are the safe inputs for calculators.
Usable depth of discharge and cycle life are chemistry- and product-specific. Do not assume the same figures as LiFePO4. Protection circuitry and charger compatibility matter; use the cell voltages from the datasheet.
Typical use includes phones, laptops, many tool batteries and some portable power products. Always match the charger to the pack.
NiMH
Nickel-metal hydride (NiMH) is common in replaceable consumer cells and some hybrid-vehicle contexts. Pack voltage again depends on series count; energy for runtime estimates needs Ah (or mAh) and the stated voltage.
Self-discharge and charge behaviour differ from lithium and lead-acid. Cycle life and recommended depth of discharge belong on the product data.
Typical use: AA/AAA-style rechargeables and some legacy cordless gear.
What the calculators need from you
Runtime and capacity sizing use nameplate energy (or Ah at a voltage you type), depth of discharge and efficiency. See the battery runtime calculator. Convert mAh or Ah to Wh with the mAh to Wh calculator.
For days of autonomy and bank size from a daily load, use the solar battery calculator. Enter DoD and η from the manufacturer or your own conservative assumption; do not treat the qualitative remarks above as numeric defaults.