Generator size calculator
Add up running and starting watts from a load list to size a generator, including “how many watts do I need.” Type each load’s running and starting watts. Optional headroom is a percentage you enter.
Starting total uses other running loads plus the load with the largest surge increment (starting − running), assuming one motor starts at a time.
Enter values to see the result.
Results are estimates. Check ratings with the manufacturer, and use a qualified electrician for installation.
How many watts do I need?
Add the running watts of every load that will be on together. That running total is the continuous wattage the generator should cover, before any headroom you choose to add. These totals are for a fuel-powered generator: it makes its own AC, runs only as long as the fuel lasts, and produces carbon monoxide, so it belongs outdoors and away from windows, following the manufacturer.
Example, with starting watts typed from labels: a refrigerator labelled 200 W running and 600 W starting, lighting at 100 W running and starting, and a microwave at 1,000 W running and starting. The running total is 200 + 100 + 1,000 = 1,300 W. The starting total, assuming one motor starts at a time, is 1,300 − 200 + 600 = 1,700 W (the refrigerator has the largest surge increment, 400 W). With 20% headroom those figures become 1,560 W and 2,040 W.
What size generator do I need?
Choose a generator whose running (or rated) watts cover the running total, and whose starting (or surge) watts cover the starting total, after any headroom you entered. Fuel tank size then decides how long it can run at that load, which is a manufacturer figure, not something this totalling step estimates.
How many watts do I need to run my loads?
The running total of the loads that will be on together, plus headroom if you want it. For the example list that is 1,300 W, or 1,560 W with 20% headroom. A portable power station is a different kind of backup: a battery and inverter, with no combustion exhaust, sized from watt-hours as well as watts.
Starting watts vs running watts
Motors and compressors often need a short surge at start. The calculator does not apply a built-in motor multiplier; type the starting watts from the label. The starting total is the other running loads plus the load with the largest surge increment, which is the usual conservative method when only one motor starts at a time. The starting watts vs running watts guide explains that rule.
Generator size for common loads you add
Build the list from the appliances you will actually run together, with running and starting watts from each label. Leaving out a load under-sizes the machine; adding loads that never run at the same time over-sizes it. Headroom is an optional percentage you type if you want a margin above those totals.
Methodology and sources
Running total R is the sum of running watts for loads that run together.
Starting total (standard conservative consumer method): R − R_max + S_max, where max is the load with the largest surge increment (S_i − R_i). If only one motor starts at a time, this is the usual result.
Optional user-entered headroom (%) is applied after, to both figures.
This is common manufacturer-guide practice for running versus starting watts, not a numbered IEC or NEC formula.
Enter starting watts from each appliance label. The calculator uses the starting watts you type; it does not apply a built-in motor multiplier. Fuel use and runtime are manufacturer figures, and generators produce carbon monoxide, so keep them outdoors and follow the manufacturer.
For appliance energy from watts and time, use the appliance energy calculator.