Starting watts vs running watts
Motors and compressors often need more watts for a short surge at start than they need while running. The generator and inverter size calculators use the same totalling rule.
Running watts and starting watts
Running watts (sometimes called continuous watts) are the power a load draws once it is operating steadily.
Starting watts (surge watts) are the higher draw many motor loads need for a short time while the motor comes up to speed, for example a fridge compressor, well pump or circular saw. Resistive loads such as a simple heater often have starting watts equal to running watts.
Nameplate or manufacturer data is the right source for both figures. The appliance energy calculator turns watts and time into energy; it does not apply a surge multiplier.
How a load list is totalled
For loads that run together, the running total is the sum of each load’s running watts: R = Σ R_i.
The starting total uses a standard conservative consumer method: R − R_max + S_max, where max is the load with the largest surge increment (S_i − R_i). In short: keep every other load at its running watts, and for the load with the biggest start bump use its starting watts instead. If only one motor starts at a time, that is the usual result.
Optional headroom (%) is a percentage you enter afterward; it is applied to both totals. The same rule feeds the generator and inverter calculators.
This is common manufacturer sizing-guide practice for running versus starting watts, not a numbered IEC or NEC formula.
Enter starting watts from the label
Enter starting watts from the appliance label or datasheet. The calculators use the starting watts you type; they do not apply a built-in motor multiplier.
Work the totals in the generator size calculator or the inverter size calculator.
Fuel generators and carbon monoxide
Petrol, diesel and other fuel generators produce carbon monoxide. Do not run them indoors or in enclosed spaces. That is a safety fact about combustion exhaust, not a sizing rule.