Electric vs gas and heat pump cost calculator
Compare the running cost of useful heat from resistance electric heat, a heat pump and gas. You enter the heat-pump COP, the gas AFUE, and both energy rates.
Enter values to see the result.
Results are estimates. Check ratings with the manufacturer, and use a qualified electrician for installation.
Heat pump running cost
A heat pump moves heat, so the electrical energy it uses is the useful heat divided by COP: electrical kWh = useful heat kWh ÷ COP, then cost = electrical kWh × electricity rate.
Example: 10 kWh of useful heat at COP 3 and an example electricity rate of 0.20 per kWh uses 10 ÷ 3 = 3.33 kWh of electricity and costs 0.67.
Is a heat pump cheaper than gas?
It depends on COP, AFUE, and the two rates you enter. In the same example, the same 10 kWh of useful heat with a gas AFUE of 0.95 and an example gas rate of 0.06 per kWh of gas energy costs 0.63. Here gas is slightly cheaper; raise the COP or the gas rate (or lower the electricity rate) and that ranking can flip. Type your own figures rather than treating this pair as a rule.
What COP should I enter?
Use the COP (or HSPF-derived COP, if that is what you have) from the manufacturer or a rating label. Outdoor temperature changes COP, so a mild-weather rating can be optimistic in the cold. The heat pump electricity guide explains that dependence without a climate model.
What COP and AFUE mean
COP is useful heat out divided by electrical energy in. AFUE is a rated seasonal efficiency for a fuel-fired heater: useful heat divided by the fuel energy in. You enter both ratios; there is no built-in default for either one.
How the comparison is calculated
Electric resistance uses one kWh of electricity for each kWh of useful heat (COP 1). The heat-pump cost is described above. For gas, useful heat is converted to BTU with the International Table factor (NIST Special Publication 811), then divided by AFUE and by the BTU per gas unit you chose (therm, kWh of gas, or a custom figure), then multiplied by the gas rate. The three costs are for the same useful heat, so you can compare them directly.
Methodology and sources
For a heat pump delivering useful heat Q_kWh at COP:
cost_e = (Q_kWh / COP) × r_e
Resistance heat is the same formula with COP = 1.
Gas: convert useful heat to BTU with the International Table factor (NIST Special Publication 811), then:
cost_g = (Q_BTU / (AFUE × T)) × r_g
where T is BTU per gas unit. Therm mode uses the usual US convention of T = 100,000 International Table BTU per therm. “kWh of gas” mode uses the NIST SP 811 kWh-to-BTU factor so the rate is per kilowatt-hour of gas energy. Custom mode lets you type any BTU-per-unit figure (for example a calorific value for m³).
COP as useful heat divided by electrical input is the usual definition used in DOE and ENERGY STAR heat-pump explainers. AFUE is a rated seasonal efficiency (DOE definition). kWh and BTU convert with the International Table factor in NIST Special Publication 811. There are no built-in default COP or AFUE values; you enter them.
For BTU ↔ watts or kWh ↔ BTU alone, use the BTU to watts converter.