UPS, inverter, power station or generator?

UPS, inverter, portable power station and fuel generator solve different backup jobs. Match the kind of tool to outage length and load, then size it with the calculators.

UPS: short outages and a clean shutdown

A UPS is built to bridge brief interruptions or to shut down equipment cleanly. It sits between the wall and a limited set of loads. Types and VA versus watts are covered in how a UPS works.

Estimate discharge time and a minimum VA size with the UPS runtime calculator. Real manufacturer curves are not linear with load; the calculator’s Wh model is an estimate only.

Inverter: battery-backed AC for chosen loads

A standalone inverter (with a battery bank you supply) turns stored DC into AC for the loads you wire or plug in. It is the right kind of tool when you want configurable storage and AC output without a fuel engine. Waveform and architecture notes: types of inverters.

Size continuous and surge watts from a load list with the inverter size calculator. Starting versus running watts: starting watts vs running watts.

Power station: portable AC in one pack

A portable power station is a battery-plus-inverter package with built-in outlets, useful when you need to move the backup or avoid a DIY DC bank. See what is a portable power station?.

Estimate runtime (and optional solar recharge if you enter the inputs) with the power station runtime calculator.

Generator: longer outages and larger house loads

A fuel generator can support larger running and starting loads for as long as you have fuel and a safe place to run it. It is a different kind of tool from battery backup: continuous energy from combustion, not from stored Wh.

Fuel generators produce carbon monoxide. Do not run them indoors or in enclosed spaces.

Add running and starting watts with the generator size calculator. The same surge-increment rule as the inverter tool applies.

How to choose a backup

Brief flicker or orderly shutdown of a PC or network stack → UPS. Fixed or expandable battery AC for selected circuits or outlets → inverter + battery. Grab-and-go AC without assembling parts → power station. Multi-hour or whole-house-class loads where fuel is acceptable → generator (often alongside a UPS for the transfer gap).

Many setups combine more than one of these. Use the matching calculator for each role. Installation, transfer switches and electrical-code questions belong with a qualified electrician.