Solar charge controller calculator
Estimate charge-controller current from array watts and battery voltage. The safety factor defaults to 1.00; you can raise it if you want a margin.
The factor defaults to 1.00 (no margin). A factor of 1.25 is a common optional margin some installers use; raise it yourself if you want that headroom.
Enter values to see the result.
Controller current comes from the array watts, battery voltage and safety factor you type. It is not PVWatts, not a location tool, and not a payback estimator.
Results are estimates. Check ratings with the manufacturer, and use a qualified electrician for installation.
What size charge controller do I need?
Controller current is I = (array watts ÷ battery volts) × safety factor. The safety factor defaults to 1.00. A factor of 1.25 appears in NEC 690.8 for PV current sizing; type 1.25 if you want that optional margin.
Example: a 1,000 W array on a 12 V battery is 1,000 ÷ 12 = 83.3 A at factor 1.00, and 104.2 A at factor 1.25. Choose a controller whose rated charging current is at least that figure, and whose input voltage window fits the array.
| Array | 12 V | 24 V | 48 V |
|---|---|---|---|
| 200 W | 16.7 A | 8.3 A | 4.2 A |
| 400 W | 33.3 A | 16.7 A | 8.3 A |
| 1,000 W | 83.3 A | 41.7 A | 20.8 A |
| 2,000 W | 166.7 A | 83.3 A | 41.7 A |
What size charge controller for 1,000 watts of solar?
83.3 A on a 12 V bank at factor 1.00, or 104.2 A with a 1.25 margin. On a 24 V bank those figures are 41.7 A and 52.1 A; on 48 V, 20.8 A and 26.0 A.
MPPT vs PWM sizing
Both types are sized from charging current into the battery, so the arithmetic above is the same starting point. MPPT controllers also have a maximum array voltage and sometimes a maximum array wattage; PWM controllers are usually closer to battery voltage on the input. The PWM vs MPPT guide compares the two families; you choose the type from the datasheet.
12 V, 24 V and 48 V examples
For the same 1,000 W array, raising the battery voltage cuts the current, as the table shows: 83.3 A at 12 V, 41.7 A at 24 V, 20.8 A at 48 V, at factor 1.00. That is why larger systems often use a higher battery voltage, alongside the inverter DC-current questions on the inverter size page.
Methodology and sources
Controller current from array power and battery voltage:
I = (P_array,W / V_battery) × f
I = P/V follows from power = voltage × current. The factor f is a safety margin you enter; the field defaults to 1.00.
A factor of 1.25 is widely used and appears in NEC 690.8 (PV current sizing). Type 1.25 if you want that optional margin; the default remains 1.00.